q-maxLUXE-pro

Q-switched & Long-pulsed Nd:YAG Laser

Q-MaxLUXE ensures significant power output for pigment procedures, maintaining consistent performance across a wide treatment area. The even distribution of energy improves safety and effectiveness, reducing the likelihood of skin thermal injury while selectively removing pigments in the dermis.

Moreover, the PTP mode is designed to offer a more comfortable experience with reduced pain and faster regeneration compared to the single-pulse mode.

In addition to the advantages of Q-MaxLUXE, the enhanced
Q-ProLUXE model includes an additional long-pulsed mode that can be used for both hair removal and the treatment of vascular lesions.

Flat top-hat beam profile

Both Q-MaxLUXE and Q-ProLUXE exhibit a flat top-hat beam profile, ensuring uniform and consistent energy delivery to the target area.

q3

Dual-pulse with less skin damage (PTP)

By employing the PTP mode, both Q-MaxLUXE and Q-ProLUXE have the capability to emit consecutive dual pulses at a maximum energy of 1.8 J. In contrast to the single-pulse mode, this configuration allows for the delivery of twice the number of pulses, each with nearly half the energy per pulse. The advantage lies in its ability to minimize treatment discomfort, as it avoids damaging normal surrounding skin tissues, a drawback associated with the single-pulse mode. Consequently, the reduced likelihood of side effects is achieved without compromising clinical results, and in most of cases, may even yield better clinical outcomes.

 

The transmission of a high energy level (e.g. 1.8J) in a single instance has the potential to harm the skin. Due to the fact physicians tend to administer less energy to the skin compared to PTP, therefore the photothermal effect necessary for collagen regeneration may not reach a sufficient level.

 

In PTP mode, double the number of laser beams are administered, providing increased energy and vibration to effectively target and destroy melanin pigment. Additionally, this mode ensures that the photothermal effect required for collagen regeneration reaches a sufficient level.

1064 nm long-pulsed mode for more indications*

In addition to the advantages of Q-MaxLUXE, the enhanced
Q-ProLUXE model includes an additional long-pulsed mode that can be used for both hair removal and the treatment of vascular lesions.

* Q-ProLUXE only

Various handpieces

With the diverse selection of handpieces provided by Q-MaxLUXE and Q-ProLUXE, physicians can administer treatments to patients at the optimal settings.

Flat top-hat beam profile

Consecutive dual pulses upto 1.8 J

2 Zoom,
4 Dye HPs

1064, 532, 585, 595, 650, 660 nm

1064 nm long-pulsed mode for more indications

* Q-ProLUXE only

Indication & Technical Specification

Pigmentation

  • Melasma
  • Café au lait
  • Freckle
  • Nevus of Ota
  • Solar Lentigo
  • ABNOM
  • Seborrheic Keratosis
  • PIH
  • Dyschromia

Rejuvenation

Tattoo Removal

  • Wrinkles
  • Black
  • Scars
  • Colored
  • Pores

Device

Q-MaxLUXE

Laser Type Nd:YAG
Wavelength 1064, 532, 585, 595, 650, 660 nm
Energy Max. 1.0 J @1064 nm (single) / Max. 1.8 J @1064 nm (double)
Max. 2.3 J @1064 nm (genesis) / N/A @1064 nm long pulse
Max. 500 mJ @532 nm (single) / Max. 500mJ @532 nm (double)
Max. 250 mJ @585 nm / Max. 150mJ @650 nm
Pulse Duration 5-8 ns / 330µs
Spot Size 2-10 mm @1064/532 nm
2 mm @585/595/650/660 nm
Frequency 2-10 Hz @1064/532 nm
1-2 Hz @585/595/650/660 nm
Aiming Beam Diode 650 nm

Device

Q-ProLUXE

Laser Type Nd:YAG
Wavelength 1064, 532, 585, 595, 650, 660 nm
Energy Max. 1.0 J @1064 nm (single) / Max. 1.8 J @1064 nm (double)
Max. 4.5 J @1064 nm (genesis) / 50 J @1064 nm long pulse
Max. 500 mJ @532 nm (single) / Max. 500mJ @532 nm (double)
Max. 250 mJ @585 nm / Max. 150mJ @650 nm
Pulse Duration 5-8 ns / 330µs / Max. 30 ms
Spot Size 2-10 mm @1064/532 nm / 11-15 mm @1054/532 nm
2 mm @585/595/650/660 nm
Frequency 2-10 Hz @1064/532 nm
1-2 Hz @585/595/650/660 nm
Aiming Beam Diode 650 nm