liftLUXE

Fractional RF Micro-needle

LiftLUXE is a groundbreaking fractional radiofrequency micro-needle device, innovatively designed to overcome the drawbacks associated with traditional lasers that can potentially damage the skin surface as they invariably penetrate through it.

 

Differentiating itself, LiftLUXE employs insulated micro-needles that penetrate the dermis directly, delivering optimal high-frequency energy without damaging the skin surface.

 

This process forms coagulated columns, fostering healing and generating ample collagen layers. The RF capability ensures a controlled energy delivery per shot ensuring consistent ideal clinical results.

No or minimized skin surface damage

The drawback associated with traditional lasers is that they can potentially damage the skin surface as they invariably penetrate through it.

On the other hand, LiftLUXE often employs insulated
micro-needles that penetrate the dermis directly, delivering optimal high-frequency energy without damaging the skin surface.

 

Controllable depth from 0.5 to 4.0 mm

The physician can adjust the penetration depth of the needle tip based on the targeted depth within the skin. Through manipulation of the device settings in the user interface, the needles depth can range from 0.5 to 4.0 mm beneath the skin surface.

Technology and skin reaction

In a fractional RF microneedle system, the choice between insulated and non-insulated needles plays a crucial role in determining the impact on skin damage and tissue coagulation. Choosing between insulated and non-insulated needles depends on the treatment goals.

Only 1 to 2 days of minimal downtime

The skin surface damage when treated with LiftLUXE is minimized as the insulated micro-needles penetrate the dermis directly. This results in a minimal downtime of only 1 to 2 days after the treatment, allowing patients to swiftly resume their normal activities.

Tips for different clinical goals

No or minimized skin surface damage

1 to 2 days only

Tips for different clinical goals

Controllable from 0.5 to 4.0 mm

Auto or Manual operation mode

Easy access to smart treatment protocol

 

 

Indication & Technical Specification

Rejuvenation

Skin Toning

  • Wrinkles
  • Dyschromia
  • Pores
  • Hyperpigmentation
  • Scars
  • Striae Distensae

Skin Tightening

Sweating

  • Laxity / Lifting
  • Hyperhidrosis
  • Turkey neck
  • Axillary osmidrosis

Energy Type

RF Microoneedle

Power 40 W
Repeat Time 0.5 – 3.0 ms OFF
Depth Level 0.5 – 4.0 mm
Frequency 1 – 2 MHz
Output Level Single shot: Level 1 – 50
Double shot: Level 1 – 100
Operation Area 15 x 15 mm